ESCAPE 1800-I WOOD INSERT TRIO (35 FT)
Please note that all heaters will be delivered via curbside delivery.
* Some conditions apply. Please read our shipping policy.
Details
Ideal for heating up to 2,100 ft², the Escape 1800 is the ultimate versatile wood insert! With only 1.54 g/h of particulate emissions, this non-catalytic appliance gives off up to 75,000 BTU/h. The Escape 1800 is the perfect choice to update your masonry fireplace and make it efficient!
Included: 6'' liner kit (35' Vortex flexible stainless steel liner, connector, 13'' x 13'' top plate, chimney cap with no screen), 32'' x 50'' faceplate with brushed nickel trim, blower, ceramic glass, ash lip, air damper
- - Burn time up to 8 hours
- - Up to 20'' logs
- - 2.4 ft³ firebox
- - Robust 5/16'' steel
- - EPA certified
- - Proudly made in Canada
- - Limited lifetime warranty
- - Weight : 495 lbs
Options: firescreen, fresh air intake
Features
SPECIFICATIONS
Fuel type | Dry cordwood (16" recommended) |
Recommended heating area (9) | 500 - 2,100 ft² |
Overall firebox volume | 2.4 ft³ |
EPA loading volume | 2.02 ft³ |
Maximum burn time (9) | 8 h |
Maximum heat output-dry cordwood (4) | 75,000 BTU/h (22.0 kW) |
Minimum overall heat output rate (4) (5) | 14,800 BTU/h (4.34 kW) |
Maximum overall heat output rate (4) (5) | 28,600 BTU/h (8.38 kW) |
Average overall efficiency-dry cordwood (HHV) (5) (6) | 69 % |
Average overall efficiency-dry cordwood (LHV) (5) (7) | 74 % |
Optimum efficiency (1) (2) | 77 % |
Optimum heat transfer efficiency (8) | 75 % |
Average particulate emission rate (3) | 1.54 g/h |
Average CO (10) | 89.4 g/h |
Size | Large |
Premium quality blower included (CFM) | 144 |
Certified according to applicable standards | By an accredited laboratory (CAN/USA) |
Combustion technology | Non-catalytic |
Stainless-steel secondary-air system | Yes |
Flue outlet diameter | 6" |
Distance-center of the flue outlet to back unit | 6 7/8" |
Distance-center of the flue outlet to side unit | 13 1/2" |
Chimney diameter | 6" |
Type of chimney | Liner - ULC-S635, CAN/ULC-S640, UL1777 |
Minimum chimney height | 12' |
Overall dimension (Width) | 28 3/8" |
Overall dimension (Height) | 23 1/8" |
Overall dimension (Depth) | 26 3/8" |
Door type | Single, glass with cast iron frame |
Door opening size (Width) | 17 1/2" |
Door opening size (Height) | 9" |
Glass type | Ceramic glass |
Glass surface - W x H | 16" x 9 1/4" |
Firebox size (Width) | 21" |
Firebox size (Height) | 11 7/8" |
Firebox size (Depth) | 16 1/2" |
Maximum log length | 20" |
Log positioning | Loading over width |
Firebox lined with refractory bricks | Yes |
Baffle type | High quality vermiculite |
Minimum fireplace opening (Height) | 23 3/8" |
Minimum fireplace opening (Width) | 28 7/8" |
Minimum fireplace opening (Depth) | 15 3/4" |
High-efficiency certified appliance | Yes, EPA 2020 approved |
Canadian Standard (emissions) | CSA B415.1-10 |
USA Standard (emissions) | EPA / ASTM WK47329 |
Canadian Standard (safety) | ULC S628 |
USA Standard (safety) | UL 1482, UL 737 |
Steel thickness-body | 3/16" |
Steel thickness-top | 5/16" |
Warranty | Limited lifetime |
Shipping weight | 405 lb (178 kg) |
CLEARANCE TO COMBUSTIBLES*
See user manual for other installation requirements.
Canada | United States | |
Clearance - Combustible side wall to unit | 16" | 16" |
Clearance - Combustible side mantle to unit | 9" | 9" |
Clearance - Combustible top mantle to unit | 27" | 27" |
Clearance - Top of the unit to a 12" combustible mantle shelf | 27" | 27" |
Clearance - Base of the unit to ceiling** | 84" | 84" |
**Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.
1. Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
2. Optimum overall efficiency at a specific burn rate (LHV).
3. This appliance is officially tested and certified by an independent agency.
4. The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
5. As measured per CSA B415.1-10 stack loss method.
6. Higher Heating Value of the fuel.
7. Lower Heating Value of the fuel.
8. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
9. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
10. Carbon monoxyde.