SPARK II WOOD STOVE

SPARK II WOOD STOVE
CA$1,149.00
SKU:
DB03401
In stock
Qty: 20

Please note that all heaters will be delivered via curbside delivery.
* Some conditions apply. Please read our shipping policy.

Details

Amongst the most compact on the market, our Spark II wood stove can heat ​​up to 1,200 ft² with a maximum heat output of 45,000 BTU/h. Non-catalytic and EPA certified at 1.8 g/h, this model can efficiently heat small spaces. The bottom of its combustion chamber is deeper than other models in its category and allows a greater accumulation of ashes, and thus to be able to empty them much less frequently. Packaged in a rigid cardboard box for ease of transport, this appliance requires simple assembly.

Included: steel legs, air deflector, ceramic glass, cast iron door with adjustable hinges, ash lip, air damper

  • - Up to 5 hours burn time
  • - Up to 17" logs
  • - 1.55 ft³ firebox
  • - EPA certified
  • - Proudly made in Canada
  • - Limited lifetime warranty
  • - Certified for mobile home and alcove installation
  • - Weight : 242 lbs

Options: blower, thermodisc, firescreen, fresh air intake kit

Features

SPECIFICATIONS

Fuel type Dry cordwood (16" recommended)
Recommended heating area (9) 250 - 1,200 ft²
Overall firebox volume 1.7 ft³
EPA loading volume 1.55 ft³
Maximum burn time (9) 5 h
Maximum heat output-dry cordwood (4) 45,000 BTU/h (13.19 kW)
Minimum overall heat output rate (4) (5) 12,124 BTU/h (3.55 kW)
Maximum overall heat output rate (4) (5) 26,700 BTU/h (7.83 kW)
Average overall efficiency-dry cordwood (HHV) (5) (6) 74 %
Average overall efficiency-dry cordwood (LHV) (5) (7) 79 %
Optimum efficiency (1) (2) 80 %
Optimum heat transfer efficiency (8) 79 %
Average particulate emission rate (3) 1.8 g/h
Average CO (10) 74 g/h
Size Small
Alcove installation approved Yes
Mobile home approved Yes, with fresh air intake
Premium quality blower included (CFM) Optional
Certified according to applicable standards By an accredited laboratory (CAN/USA)
Combustion technology Non-catalytic
Stainless-steel secondary-air system Yes
Flue outlet diameter 6"
Distance-center of the flue outlet to back unit 6 5/8"
Distance-center of the flue outlet to side unit 9 1/4"
Chimney diameter 6"
Type of chimney CAN/ULC S629, UL 103 HT (2100 °F)
Minimum chimney height 12'
Overall dimension (Width) 18 1/2"
Overall dimension (Depth) 28 7/8"
Overall dimension (Height) 28 3/4"
Door type Single, glass with cast iron frame
Door opening size (Width) 12"
Door opening size (Height) 7 5/8"
Glass type Ceramic glass
Glass surface - W x H 10 1/4" x 8 1/2"
Firebox size (Width) 14 1/4"
Firebox size (Height) 11 3/4"
Firebox size (Depth) 19 1/8"
Maximum log length 17"
Log positioning Loading over depth
Firebox lined with refractory bricks Yes
Baffle type High quality vermiculite
High-efficiency certified appliance Yes, EPA 2020 approved
Canadian Standard (emissions) CSA B415.1-10
USA Standard (emissions) EPA
Canadian Standard (safety) ULC S627
USA Standard (safety) UL 1482, UL 737
Steel thickness-body 3/16"
Steel thickness-top 1/4"
Warranty Limited lifetime
Shipping weight 235 lb (107 kg)


CLEARANCE TO COMBUSTIBLES*

Applies to 84" ceiling installation only.
See user manual for other installation requirements.

Canada United States
Single wall pipe  Double wall pipe Single wall pipe Double wall pipe
Clearance - Back wall 14" 6" 12" 6"
Clearance - Side wall 18" 18" 18" 18"
Clearance - Corner 11" 7" 11" 7"
Clearance - Base of the unit to ceiling** 84" 84" 84" 84"


*The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
**Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.

1. Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
2. Optimum overall efficiency at a specific burn rate (LHV).
3. This appliance is officially tested and certified by an independent agency.
4. The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
5. As measured per CSA B415.1-10 stack loss method.
6. Higher Heating Value of the fuel.
7. Lower Heating Value of the fuel.
8. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
9. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
10. Carbon monoxyde.

Reviews

Write Your Own Review
You're reviewing:SPARK II WOOD STOVE
Your Rating