ESCAPE 1800-I WOOD INSERT

ESCAPE 1800-I WOOD INSERT
US$1,749.00
SKU:
DB03125
In stock
Qty: 95

Description

  Is this wood insert qualified for a Tax Credit?  
Consult the eligible models list.

Everything you need to know about the 26% Tax Credit :
It covers the cost of the appliance, chimney, air distribution ducts, labor for installation and related material.
Learn more

Please note that all heaters will be delivered via curbside delivery.
* Some conditions apply. Please read our shipping policy.

Details

Ideal for heating up to 2,100 ft², the Escape 1800 is the ultimate versatile wood insert! With only 1.54 g/h of particulate emissions, this non-catalytic appliance gives off up to 75,000 BTU/h. The Escape 1800 is the perfect choice to update your masonry fireplace and make it efficient!

Included: blower, ceramic glass, ash lip, air damper

  • - Burn time up to 8 hours
  • - Up to 20'' logs
  • - 2.4 ft³ firebox
  • - Robust 5/16'' steel  
  • - EPA certified
  • - Proudly made in Canada
  • - Limited lifetime warranty
  • - Weight : 392 lbs

Options: faceplate (regular or large) with brushed nickel trim or cuttable faceplate, firescreen, fresh air intake

Features

SPECIFICATIONS

Fuel type Dry cordwood (16" recommended)
Recommended heating area (9) 500 - 2,100 ft²
Overall firebox volume 2.4 ft³
EPA loading volume 2.02 ft³
Maximum burn time (9) 8 h
Maximum heat output-dry cordwood (4) 75,000 BTU/h (22.0 kW)
Minimum overall heat output rate (4) (5) 14,800 BTU/h (4.34 kW)
Maximum overall heat output rate (4) (5) 28,600 BTU/h (8.38 kW)
Average overall efficiency-dry cordwood (HHV) (5) (6) 69 %
Average overall efficiency-dry cordwood (LHV) (5) (7) 74 %
Optimum efficiency (1) (2) 77 %
Optimum heat transfer efficiency (8) 75 %
Average particulate emission rate (3) 1.54 g/h
Average CO (10) 89.4 g/h
Size Large
Premium quality blower included (CFM) 144
Certified according to applicable standards By an accredited laboratory (CAN/USA)
Combustion technology Non-catalytic
Stainless-steel secondary-air system Yes
Flue outlet diameter 6"
Distance-center of the flue outlet to back unit 6 7/8"
Distance-center of the flue outlet to side unit 13 1/2"
Chimney diameter 6"
Type of chimney Liner - ULC-S635, CAN/ULC-S640, UL1777
Minimum chimney height 12'
Overall dimension (Width) 28 3/8"
Overall dimension (Height) 23 1/8"
Overall dimension (Depth) 26 3/8"
Door type Single, glass with cast iron frame
Door opening size (Width) 17 1/2"
Door opening size (Height) 9"
Glass type Ceramic glass
Glass surface - W x H 16" x 9 1/4"
Firebox size (Width) 21"
Firebox size (Height) 11 7/8"
Firebox size (Depth) 16 1/2"
Maximum log length 20"
Log positioning Loading over width
Firebox lined with refractory bricks Yes
Baffle type High quality vermiculite
Minimum fireplace opening (Height) 23 3/8"
Minimum fireplace opening (Width) 28 7/8"
Minimum fireplace opening (Depth) 15 3/4"
High-efficiency certified appliance Yes, EPA 2020 approved
Canadian Standard (emissions) CSA B415.1-10
USA Standard (emissions) EPA / ASTM WK47329
Canadian Standard (safety) ULC S628
USA Standard (safety) UL 1482, UL 737
Steel thickness-body 3/16"
Steel thickness-top 5/16"
Warranty Limited lifetime
Shipping weight 405 lb (178 kg)



CLEARANCE TO COMBUSTIBLES*

See user manual for other installation requirements.

Canada United States
Clearance - Combustible side wall to unit 16" 16"
Clearance - Combustible side mantle to unit 9" 9"
Clearance - Combustible top mantle to unit 27" 27"
Clearance - Top of the unit to a 12" combustible mantle shelf 27" 27"
Clearance - Base of the unit to ceiling** 84" 84"


*The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).

**Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.

1. Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
2. Optimum overall efficiency at a specific burn rate (LHV).
3. This appliance is officially tested and certified by an independent agency.
4. The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
5. As measured per CSA B415.1-10 stack loss method.
6. Higher Heating Value of the fuel.
7. Lower Heating Value of the fuel.
8. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
9. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
10. Carbon monoxyde.

Reviews 3

Write Your Own Review
You're reviewing:ESCAPE 1800-I WOOD INSERT
Your Rating